1. IntroductionIM902 is a 90A magnetic latching relay with anti-surge of 3kA and over-voltage/under-voltage protection function.The main advantages are: Max. Switching Current 90A , Rated Coil Consumption 1.5W/2W, Dimension: 38*30*16.5mm, IEC62055-31 UC2 Certified, Anti-surge up to 3KA, effectively suitable for over-voltage and under-voltage protectors2.Technical ParametersRated Load90A 250VACContact Form1A/BContact MaterialAgSnO2Max. Switching Voltage250VACMax. Switching Current90AMax. Switching Power22500VAContact Resistance<1mΩPick-up Time≤20msRelease
1.Overview:● CT Assembled, Max. Switching Current: 90A● Rated Coil Consumption:3.0/6W(20ms)● Dimension:98*40*35.7mm● Anti-shock, Reliable, Environment-friendly● Widely used for three phase / 3 phase smart meter2.Specification:Basic DataDimension(mm)98*40*35.7Weight ( g )/Contact Arrangement3A/3BContact MaterialAgSnO2Ambient Temperature-40~+70ºCAmbient Humidity45%~90%RHVibration10~55Hz,1.5mm(DA)Specification DataNominal Voltage6~48VDCPower ConsumptionSingle Coil:3.0W, Dual Coil:6.0WMax. Switching Voltage250VACMax. Switching Current90AMax. Switching Power22500 VAContact
1.Overview:● CT Assembled, Max. Switching Current: 90A● Rated Coil Consumption:3.0/6W(20ms)● Dimension:98*40*35.7mm● Anti-shock, Reliable, Environment-friendly● Widely used for three phase / 3 phase smart meter2.Specification:Basic DataDimension(mm)98*40*35.7Weight ( g )/Contact Arrangement3A/3BContact MaterialAgSnO2Ambient Temperature-40~+70ºCAmbient Humidity45%~90%RHVibration10~55Hz,1.5mm(DA)Specification DataNominal Voltage6~48VDCPower ConsumptionSingle Coil:3.0W, Dual Coil:6.0WMax. Switching Voltage250VACMax. Switching Current90AMax. Switching Power22500 VAContact
1.Main Features:● Contact Form:3A/B● Max. Switching Current:150A● Rated Coil Consumption:3.0/6.0W (50ms)● Dimension:110*68*35mm● Widely Used for Industrial Control● Wide Application for Energy Meter, RCCB, EV Charger, IOT Device 2.Technical Parameters:Main ParametersRated Load150A 250VACContact Form3A/3BContact MaterialAgSnO2Max. Switching Voltage250VACMax. Switching Current150AMax. Switching Power37500VAContact Resistance<2mΩPick-up Time50msRelease Time50msElectrical Endurance10000 CyclesMechanical Endurance100000 CyclesTemp. Rise≤55K When Ambient
1.Main Features:● Max. Switching Current:120A● Rated Coil Consumption:3.0/6W(30ms)● CT Assembled, Low Consumption, Pulse Driving● Anti-shock, Reliable, Environment-friendly● Dimension:78.6*40.3*37.8mm 2.Technical Parameters:Main ParametersRated Load120A 250VACContact Form3A/BContact MaterialAgSnO2Max. Switching Voltage250VACMax. Switching Current120AMax. Switching Power30000VAContact Resistance<2.0mΩPick-up Time30msRelease Time30msElectrical Endurance10000 CyclesMechanical Endurance100000 CyclesTemp. Rise≦55k Other ParametersInsulation Resistance1000
1.Main Features:● Max. Switching Current:120A● Rated Coil Consumption:3.0/6W(30ms)● CT Assembled, Low Consumption, Pulse Driving● Anti-shock, Reliable, Environment-friendly● Dimension:78.6*40.3*37.8mm 2.Technical Parameters:Main ParametersRated Load120A 250VACContact Form3A/BContact MaterialAgSnO2Max. Switching Voltage250VACMax. Switching Current120AMax. Switching Power30000VAContact Resistance<2.0mΩPick-up Time30msRelease Time30msElectrical Endurance10000 CyclesMechanical Endurance100000 CyclesTemp. Rise≦55k Other ParametersInsulation Resistance1000
1.Main Features:● Max. Switching Current:120A● Rated Coil Consumption:2.0/4.0W(30ms)● Dimension:42*35*21.3mm● IEC62055-31 UC3 Certified 2.Technical Parameters:Main ParametersRated Load120A 250VACContact Form1A/BContact MaterialAgSnO2Max. Switching Voltage277VACMax. Switching Current120AMax. Switching Power33240 VAContact Resistance<2mΩPick-up Time30msRelease Time30msElectrical Endurance10000 CyclesMechanical Endurance100000 CyclesTemp. Rise≤55K When Ambient 40℃ Other ParametersInsulation Resistance1000MΩ(DC 500V)Dielectric Strength:Coil to Contact4000VAC,
1.Main Features:● Max. Switching Current:100A● Rated Coil Consumption:1.5/3W(20ms)● Dimension:39*30*18.5mm● IEC62055-31 UC3 Certified 2.Technical Parameters:Main ParametersRated Load100A 250VACContact Form1A/BContact MaterialAgSnO2Max. Switching Voltage277VACMax. Switching Current100AMax. Switching Power27700VAContact Resistance<2mΩPick-up Time20msRelease Time20msElectrical Endurance5000 CyclesMechanical Endurance100000 CyclesTemp. Rise≤55K When Ambient 40℃ Other ParametersInsulation Resistance1000MΩ(DC 500V)Dielectric Strength:Coil to Contact6000VAC,50/6
1.Main Features:● Latching relay, 100A switching capability● Impulse control within a short time, low power● The contact can stand 2200A for 10ms● Conforms to State Grid anti strong magnetic requirements● 4kV dielectric strength between coil and contact● Single or Double coils can be choose● Environmental friendly product RoHS compliant 2.Technical Parameters:Main ParametersRated Load100A 250VACContact Form1A/BContact MaterialAgSnO2Max. Switching Voltage277VACMax. Switching Current100AMax. Switching Power27700VAContact Resistance<2mΩPick-up
1.Main Features:● Latching relay, 100A switching capability● Impulse control within a short time, low power● The contact can stand 2200A for 10ms● Conforms to State Grid anti strong magnetic requirements● 4kV dielectric strength between coil and contact● Single or Double coils can be choose● Environmental friendly product RoHS compliant 2.Technical Parameters:Main ParametersRated Load100A 250VACContact Form1A/BContact MaterialAgSnO2Max. Switching Voltage277VACMax. Switching Current100AMax. Switching Power27700VAContact Resistance<2mΩPick-up
1.Main Features:● Max. Switching Current:90A● Rated Coil Consumption:1.5/3W(20ms)● Dimension:38*30*16.5mm● IEC62055-31 UC2/UC3 Certified 2.Technical Parameters:Main ParametersRated Load90A 250VACContact Form1A/BContact MaterialAgSnO2Max. Switching Voltage250VACMax. Switching Current90AMax. Switching Power22500VAContact Resistance<2mΩPick-up Time20msRelease Time20msElectrical Endurance10000 CyclesMechanical Endurance100000 CyclesTemp. Rise≤55K When Ambient 40℃ Other ParametersInsulation Resistance1000MΩ(DC 500V)Dielectric Strength:Coil to Contact4000VAC,50
1.Main Features:● Max. Switching Current:90A● Rated Coil Consumption:1.5/3W(20ms)● Dimension:38*30*16.5mm● IEC62055-31 UC2/UC3 Certified 2.Technical Parameters:Main ParametersRated Load90A 250VACContact Form1A/BContact MaterialAgSnO2Max. Switching Voltage250VACMax. Switching Current90AMax. Switching Power22500VAContact Resistance<2mΩPick-up Time20msRelease Time20msElectrical Endurance10000 CyclesMechanical Endurance100000 CyclesTemp. Rise≤55K When Ambient 40℃ Other ParametersInsulation Resistance1000MΩ(DC 500V)Dielectric Strength:Coil to Contact4000VAC,50
1.Main Features:● Max Switching Current 80A● Rated Coil Consumption: 2 / 4W(30ms)● Dielectric Strength of 4kV● Cost Efficiency & Surge Protection● Single Coil Double Coil Optional● Dual Pole Latching Relay, Double Way Control● Compact Size:62.8*35*21.8mm● External Shielding Case Available● RoHS Compliant Materials and Process● Short Circuit per IEC 62055-31 UC2 Certificate● Custom Assemblies with Integrated Shunts, Flex-wire and Copper Extensions and Brass Terminals● Wide Application for Energy Meter, RCCB, EV Charger, IOT Device 2.Technical Parameters:Main ParametersRated Load8
1.Main Features:● Max Switching Current 80A● Rated Coil Consumption: 2 / 4W(30ms)● Dielectric Strength of 4kV● Cost Efficiency & Surge Protection● Single Coil Double Coil Optional● Dual Pole Latching Relay, Double Way Control● Compact Size:62.8*35*21.8mm● External Shielding Case Available● RoHS Compliant Materials and Process● Short Circuit per IEC 62055-31 UC2 Certificate● Custom Assemblies with Integrated Shunts, Flex-wire and Copper Extensions and Brass Terminals● Wide Application for Energy Meter, RCCB, EV Charger, IOT Device 2.Technical Parameters:Main ParametersRated Load8
1.Main Features:● Max Switching Current 60A(32A 40A)● Rated Coil Consumption: 1.5 / 3W(20ms)● Dielectric Strength of 4kV● Cost Efficiency & Surge Protection● Single Coil Double Coil Optional● Compact Size:38*30*16.5mm● External Shielding Case Available● RoHS Compliant Materials and Process● Short Circuit per IEC 62055-31 UC2 Certificate● Custom Assemblies with Integrated Shunts, Flex-wire and Copper Extensions and Brass Terminals● Wide Application for Energy Meter,RCCB, EV Charger, IOT Device 2.Technical Parameters:Main ParametersRated Load60A 250VACContact Form1A/BContact
1.Main Features:● Max Switching Current 60A(32A 40A)● Rated Coil Consumption: 1.5 / 3W(20ms)● Dielectric Strength of 4kV● Cost Efficiency & Surge Protection● Single Coil Double Coil Optional● Compact Size:38*30*16.5mm● External Shielding Case Available● RoHS Compliant Materials and Process● Short Circuit per IEC 62055-31 UC2 Certificate● Custom Assemblies with Integrated Shunts, Flex-wire and Copper Extensions and Brass Terminals● Wide Application for Energy Meter,RCCB, EV Charger, IOT Device 2.Technical Parameters:Main ParametersRated Load60A 250VACContact Form1A/BContact